The paper describes experimental results of determining scales of turbulent eddies in diffusion flames. The results are obtained by analyzing a set of 2D cross-sections cut from 3D semi-transparent flames. The comparison of data obtained by using the particle image velocimetry (PIV) method and infrared (IR) thermography is presented to demonstrate similarity between hydro- and thermodynamic parameters.