In this paper, the experimental studies of copper bromide vapor brightness amplifiers operating at high pulse repetition frequencies are presented. The obtained results show that the injection of active hydrogen-containing additives allows to increase the radiation (gain) pulse repetition frequency in active elements with a diameter of the active zone larger than 1 cm.
18th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices : proceedings, Erlagol, Altai Republic, 29 June - 3 July, 2017. Novosibirsk, 2017. P. 341-344